CAOPONR在线视频进入,亚洲国产不卡久久久久久,狠狠狼鲁亚洲综合网,欧美色偷偷

EPC Products Transducer & Data logger Strain Gauge Bolt Strain Bolt strain gauge series BTM/BTMC
產(chǎn)品中心
Bolt strain gauge series BTM/BTMC

Model:BTM/BTMC

Use:These gauges are used for measurement of tensile strain of bolt.

Standard:

These gauges are used for measurement of tensile strain of bolt. They are simply inserted into pre-drilled hole in the bolt with exclusive adhesives. This method is recommendable when an ordinary strain gauges can not be mounted on the bolt surface. Accurate tensile force measurement is possible by calibrating the bolt after installing the bolt gauges.


Applicable
specimen
Bolt M10 or larger
Backing
Special
plastics
Operational
temperature(°C)
-10 ~ +80°C
Element
Cu-Ni
Temperature
compensation range(°C)
Strain limit
0.5%
(5000×10-6 strain)
Applicable adhesive
A-2(BTM) 
CN(BTMC)
Fatigue life
at room temperature
 



series BTM



Single-element (G.F. 2.1 approx.)

BTM

BTM-1C/BTM-6C/BTM-6CTB

Type
Gauge
length
(mm)
Gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Resistance
(Ω)
Applicable
hole diameter
(mm)
BTM-1C 1 0.7 5.6 1.4 120 ?1.6
BTM-6C 6 1.0 12.0 1.7 120 ?2.0
BTM-6CTA 6 1.0 12.0 1.7 120 ?2.0
Each package contains 10 gauges.



Single-element



(G.F. 2.1 approx.)

Type
Gauge
length
(mm)
Gauge
center
a (mm)
Backing
diameter
b (mm)
Resistance
(Ω)
Applicable
hole diameter
(mm)
BTMC-05-D10-003LE 0.5 5 ?0.9 120 ?1.0
BTMC-1-D16-003LE 1 5 ?1.5 120 ?1.6
BTMC-3-D20-003LE 3 10 ?1.9 120 ?2.0
Each package contains 10 gauges.series BTMC


Project Case
Solution
Download
相關(guān)標(biāo)簽
TML,Tokyo Measuring Instruments Laboratory