Process Capabilities
-
Operation of a continuous HTST pasteurisation plant using selected liquid foods
-
Learning the importance of Clean-In-Place (CIP) procedures
-
Varying and controlling holding times
-
Measuring heat transfer coefficients in a plate heat exchanger, for various plate and gasket configurations
-
Measuring heat recovery in a regenerator
Features/Benefits
-
Miniature plate heat exchanger
-
Fully self-contained design with integral hot water system
-
Choice of holding tubes
-
Variable product temperature and holding time
-
Control console incorporating comprehensive instrumentation
-
CIP facility benchtop operation
-
Tests can be carried out quickly and easily
-
Simulates the conditions used in a production plant
-
Small quantities of liquid product can be processed
Description
This self-contained laboratory unit is suitable for HTST
(high temperature, short time) pasteurisation of up to 20 litres/hour of a wide variety of low-viscosity liquid foods. Products that may be pasteurised include raw milk, nectars, fruit juices, skimmed milk,
ice-cream mix, soft drinks, pharmaceuticals and margarine emulsion.
A CIP (clean-in-place) facility is incorporated which allows disinfection, pre-rinsing, detergent washing and final rinsing. The ability to vary process conditions has been built into the unit in the form of the following features:
-
Variable speed, peristaltic, hygienic feed pump allowing flow rate variations
-
Plate-type stainless steel heat exchanger – the cooling, regenerating and heating sections, mounted on a common frame work, are easily dismantled to allow re-configuration and inspection of the heat transfer surfaces
-
Electrically heated hot water circulating system for both pasteurisation and CIP cycles – any required holding tube outlet temperature is set on the indicating microprocessor-based power output controller of the water heater
-
Stainless steel holding tube, allowing holding times between five seconds and two minutes
-
Flow rates of feed pump, cooling water and hot water are monitored accurately
-
Temperatures in the system are monitored with thermocouple sensors at each of six chosen locations (nine available)
-
Maximum process temperature 85°C
Download
相關(guān)標(biāo)簽
Armfield,FT43,Laboratory Pasteuriser